Source / pinned edition
Electrical
Source of package us.cfr.osha_1910_subpart_s · 29 CFR Part 1910 Subpart S
- work
- urn:us:cfr:osha-1910-subpart-s#CFR29_PART1910_SUBPART_S
- number
- 29 CFR Part 1910 Subpart S
- kind
- urn:us:cfr:osha-1910-subpart-s#regulation
29 CFR Part 1910 (eCFR, редакция на 27 августа 2026)
- edition
- urn:us:cfr:osha-1910-subpart-s#CFR29_PART1910_2026
- language
- en
- officiality
- official
- materialisation
- PINNED_UNOFFICIAL_COPY
- life cycle
- —
Publications
| URI | Type | documentHash | Retrieved |
|---|---|---|---|
| https://www.ecfr.gov/api/renderer/v1/content/enhanced/2026-08-27/title-29?subtitle=B&chapter=XVII&part=1910 | text/html; charset=utf-8 | sha256:3a0c1634b9f690e709d9ddba8bcf164ba67e78cdb938994f0ef7a0901dbce6cb | 2026-09-17T00:00:00Z |
Fragments — 3
section/1910.303/b/1 · provision · referenced by: 1
en · official · sha256:bf202dd810fd6dbc7b42859e6c9b0a1159cd25b7ed51d143ddf73558a056ef07
<p class="indent-2" data-title="1910.303(b)(1)"><span class="paragraph-hierarchy"><span class="paren">(</span>1<span class="paren">)</span></span> <em class="paragraph-heading">Examination.</em> Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:</p>Referencing norms: InspectionDocumented
section/1910.303/g/1/i · provision · referenced by: 1
en · official · sha256:d1908948fcaad7688365a1cc1b178e7d200f93bc2ae028b349f5b8105e42a6ff
<p class="indent-3" data-title="1910.303(g)(1)(i)"><span class="paragraph-hierarchy"><span class="paren">(</span>i<span class="paren">)</span></span> Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:</p>Referencing norms: GeneralRequirementsMet
section/1910.333/a/1 · provision · referenced by: 1
en · official · sha256:80a82f69c80612f274537fcc61879091236b7a2d1e0f1139909a3bd070a213e8
<p class="indent-2" data-title="1910.333(a)(1)"><span class="paragraph-hierarchy"><span class="paren">(</span>1<span class="paren">)</span></span> <em class="paragraph-heading">Deenergized parts.</em> Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.</p>Referencing norms: SafeWorkPracticeMet
The hash beside the text is the sha256 of its exact bytes. It is the check that the text shown matches the one pinned in the package: a divergence fails the oracle’s static analysis.