Источник / закреплённая редакция

Electrical

Источник пакета us.cfr.osha_1910_subpart_s · 29 CFR Part 1910 Subpart S

work
urn:us:cfr:osha-1910-subpart-s#CFR29_PART1910_SUBPART_S
номер
29 CFR Part 1910 Subpart S
вид
urn:us:cfr:osha-1910-subpart-s#regulation

29 CFR Part 1910 (eCFR, редакция на 27 августа 2026)

edition
urn:us:cfr:osha-1910-subpart-s#CFR29_PART1910_2026
язык
en
официальность
official
материализация
PINNED_UNOFFICIAL_COPY
жизненный цикл
—

Публикации

URIТипdocumentHashПолучено
https://www.ecfr.gov/api/renderer/v1/content/enhanced/2026-08-27/title-29?subtitle=B&chapter=XVII&part=1910text/html; charset=utf-8sha256:3a0c1634b9f690e709d9ddba8bcf164ba67e78cdb938994f0ef7a0901dbce6cb2026-09-17T00:00:00Z

Фрагменты — 3

section/1910.303/b/1 · provision · на него ссылаются: 1

en · official · sha256:bf202dd810fd6dbc7b42859e6c9b0a1159cd25b7ed51d143ddf73558a056ef07EN

<p class="indent-2" data-title="1910.303(b)(1)"><span class="paragraph-hierarchy"><span class="paren">(</span>1<span class="paren">)</span></span> <em class="paragraph-heading">Examination.</em> Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:</p>

Ссылаются нормы: InspectionDocumented

section/1910.303/g/1/i · provision · на него ссылаются: 1

en · official · sha256:d1908948fcaad7688365a1cc1b178e7d200f93bc2ae028b349f5b8105e42a6ffEN

<p class="indent-3" data-title="1910.303(g)(1)(i)"><span class="paragraph-hierarchy"><span class="paren">(</span>i<span class="paren">)</span></span> Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:</p>

Ссылаются нормы: GeneralRequirementsMet

section/1910.333/a/1 · provision · на него ссылаются: 1

en · official · sha256:80a82f69c80612f274537fcc61879091236b7a2d1e0f1139909a3bd070a213e8EN

<p class="indent-2" data-title="1910.333(a)(1)"><span class="paragraph-hierarchy"><span class="paren">(</span>1<span class="paren">)</span></span> <em class="paragraph-heading">Deenergized parts.</em> Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.</p>

Ссылаются нормы: SafeWorkPracticeMet

Хэш рядом с текстом — sha256 его точных байтов. Он и есть проверка того, что показанный текст совпадает с закреплённым в пакете: расхождение роняет статику оракула.