Источник / закреплённая редакция

Electrical protective equipment

Источник пакета us.cfr.osha_1910_137 · 29 CFR 1910.137

work
urn:us:cfr:osha-1910-137#CFR29_1910_137
номер
29 CFR 1910.137
вид
urn:us:cfr:osha-1910-137#regulation

29 CFR 1910.137 (eCFR, редакция на 27 августа 2026)

edition
urn:us:cfr:osha-1910-137#CFR29_1910_137_2026
язык
en
официальность
official
материализация
PINNED_UNOFFICIAL_COPY
жизненный цикл
—

Публикации

URIТипdocumentHashПолучено
https://www.ecfr.gov/api/renderer/v1/content/enhanced/2026-08-27/title-29?subtitle=B&chapter=XVII&part=1910&section=1910.137text/html; charset=utf-8sha256:2a159ed81f7b4527d0d2be7d6001e090fce5a6c0de7538def425a6271e990ba22026-09-17T00:00:00Z

Фрагменты — 3

section/1910.137/c/2/viii · provision · на него ссылаются: 2

en · official · sha256:7cb4b578cabb3ea03d36c53583a62aadc35e137665367ff02bf3616d5a50097cEN

<p class="indent-3" data-title="1910.137(c)(2)(viii)"><span class="paragraph-hierarchy"><span class="paren">(</span>viii<span class="paren">)</span></span> Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5.</p>

Ссылаются нормы: NextPeriodicTestDue, PpeTestOverdue

section/1910.137/c/2/xi · provision · на него ссылаются: 1

en · official · sha256:0451b86949c887887fada7412545e91d24bbdf4e34cfd2d07aa54504810bc121EN

<p class="indent-3" data-title="1910.137(c)(2)(xi)"><span class="paragraph-hierarchy"><span class="paren">(</span>xi<span class="paren">)</span></span> Repaired insulating equipment shall be retested before it may be used by employees.</p>

Ссылаются нормы: RetestRequiredAfterRepair

section/1910.137/c/2/xii · provision · на него ссылаются: 2

en · official · sha256:033ce1c2651da94d949d6daa63614b5ab0e5224f7302581d7a1eb3ef16c958acEN

<p class="indent-3" data-title="1910.137(c)(2)(xii)"><span class="paragraph-hierarchy"><span class="paren">(</span>xii<span class="paren">)</span></span> The employer shall certify that equipment has been tested in accordance with the requirements of <a href="/on/2026-08-27/title-29/section-1910.137#p-1910.137(c)(2)(iv)" class="cfr external">paragraphs (c)(2)(iv)</a>, <a href="/on/2026-08-27/title-29/section-1910.137#p-1910.137(c)(2)(vii)(D)" class="cfr external">(c)(2)(vii)(D)</a>, <a href="/on/2026-08-27/title-29/section-1910.137#p-1910.137(c)(2)(viii)" class="cfr external">(c)(2)(viii)</a>, <a href="/on/2026-08-27/title-29/section-1910.137#p-1910.137(c)(2)(ix)" class="cfr external">(c)(2)(ix)</a>, and <a href="/on/2026-08-27/title-29/section-1910.137#p-1910.137(c)(2)(xi)" class="cfr external">(c)(2)(xi)</a> of this section. The certification shall identify the equipment that passed the test and the date it was tested and shall be made available upon request to the Assistant Secretary for Occupational Safety and Health and to employees or their authorized representatives.</p>

Ссылаются нормы: PpeTestFulfilled, PpeTestOpen

Хэш рядом с текстом — sha256 его точных байтов. Он и есть проверка того, что показанный текст совпадает с закреплённым в пакете: расхождение роняет статику оракула.